Step 1 of 6 Plan the practical
Aim
Find how the current through a component depends on the potential difference across it, for three components:
- a fixed resistor (at constant temperature)
- a filament lamp
- a diode
You plot an I–V graph (current against p.d.) for each one, with positive and negative values.
Equipment
- a variable d.c. power supply (or a battery and a variable resistor)
- an ammeter
- a voltmeter
- connecting leads
- the components: a fixed resistor, a filament lamp and a diode
- a protective resistor (to use in series with the diode)
Method
- Connect the component, the ammeter and the power supply in series.
- Connect the voltmeter across (in parallel with) the component.
- Set the supply to a low p.d. Record the p.d. on the voltmeter and the current on the ammeter.
- Increase the p.d. in steps and record V and I each time.
- Swap the connections to the power supply (reverse the p.d.) and repeat, so you have negative values.
- For the diode, use a protective resistor in series, and take lots of readings between 0.5 V and 0.8 V.
- Plot a graph of current (y-axis) against p.d. (x-axis), with both positive and negative values.
Step 2 of 6 Variables and risks
Variables: what changes, what you measure, what stays the same
The quiz needs JavaScript. The answers are in the table below.
The variables in this practical
| Variable | In this practical |
|---|---|
| Independent (what you change) | The potential difference across the component |
| Dependent (what you measure) | The current through the component |
| Control (keep the same) | The component; for the resistor, its temperature (do not leave the current on for long) |
💡 Exam tip: An I–V graph has current on the y-axis and p.d. on the x-axis.
Risks
| Hazard | What could happen | How to reduce the risk |
|---|---|---|
| Components can get hot, especially the lamp and resistors at high currents | Burns | Do not touch them while the current is on. Switch off between readings. |
| Too much current through the diode | The diode is damaged | Always use a protective resistor in series with the diode. |
| The filament lamp gets hot and can break if its rating is exceeded | Burns, and the lamp fails | Do not go above the lamp’s rated p.d. (for example 6 V). |
Step 3 of 6 Do the practical
Simulator
Build the circuit on the circuit board: drag each meter and component into a gap. Press Test my circuit – you will get a hint for each mistake. Then change the supply p.d. and record the readings.
Step 4 of 6 Results and graph
Help: how to analyse the results
Fixed resistor
A straight line through the origin. The current is directly proportional to the p.d., so the resistance stays the same (an ohmic conductor at constant temperature). Resistance = V ÷ I.
Filament lamp
An S-shaped curve. As the current increases, the filament gets hotter, so its resistance increases and the graph gets less steep. It looks the same for negative values.
Diode
Current flows in one direction only. In the forward direction there is almost no current until about 0.6 V, then the current rises steeply. In the reverse direction the resistance is very high, so the current is (almost) zero.
Step 5 of 6 Conclusion and evaluation
Conclusion
Show a model conclusion
The graph for the filament lamp is a curve. At low p.d. it is nearly straight, but as the p.d. increases the current rises more slowly, so the resistance of the lamp increases. This is because the filament gets hotter, so its ions vibrate more and the electrons collide with them more often. The graph has the same shape for negative p.d.
Errors and how to improve
- Heating (resistor): if the current is left on, the resistor warms up and its resistance changes. Switch off between readings.
- Zero error: check that both meters read zero before you start.
- Too few readings where the graph changes: for the diode, take extra readings between 0.5 V and 0.8 V.
- Meter resolution: the diode’s current is small at first. Use a meter that reads milliamps.
- Random errors: repeat readings and draw a smooth line or curve of best fit.
Step 6 of 6 Six-mark question
A student wants to find how the current through a filament lamp depends on the potential difference across it.
Describe a method the student could use. You may include a circuit diagram in your answer.
[6 marks]
Mark scheme (level of response)
| Level | What the answer needs |
|---|---|
| 3 (5–6 marks) | A detailed method in a logical order, with a correct circuit, a range of p.d. values (including negative) and a graph. |
| 2 (3–4 marks) | A method with the main steps and a mostly correct circuit, but some detail is missing. |
| 1 (1–2 marks) | Some relevant steps, but not a method someone could follow. |
| 0 | Nothing worth a mark. |
Tick the points your answer includes
Show a model answer
Connect the lamp in series with an ammeter, a variable resistor and a battery. Connect a voltmeter across the lamp. Adjust the variable resistor to give a low p.d., then record the p.d. on the voltmeter and the current on the ammeter. Change the variable resistor to get at least 8 different p.d. values, recording the current each time. Then reverse the connections to the battery and repeat to get negative values. Plot a graph of current against potential difference and draw a smooth curve of best fit.
This is an exam-style question written for this website. It is not a real AQA question.