From KS3 to GCSE
✔ You already know (KS3)
- Power stations generate electricity by turning a generator.
★ New at GCSE
- How a rotating coil generates a p.d.
- Alternator (slip rings) → AC.
- Dynamo (split-ring commutator) → DC.
- Drawing and interpreting p.d.–time graphs.
KS3 link: KS3 physics: magnets and magnetic materials, magnetic poles and fields, the Earth’s magnetism, and electromagnets.
Key ideas
Rotating coil
- As the coil rotates in the field, its sides cut field lines, so a p.d. is induced.
- The p.d. is biggest when the coil sides move across the field (coil horizontal) and zero when they move along it (coil vertical).
Alternator (AC)
- Connected using slip rings and brushes.
- The sides swap direction every half turn, so the p.d. alternates – a sine-shaped graph above and below zero.
Dynamo (DC)
- Connected using a split-ring commutator.
- The connections swap every half turn, so the output is always in the same direction – humps above zero.
- Faster rotation → bigger peak p.d. and higher frequency.
Diagrams
Key equations
| Equation | In words | Units / notes |
|---|
⚠ Watch out! Common mistakes
- An alternator uses slip rings; a dynamo uses a split ring.
- The DC from a dynamo is not steady – it varies but does not reverse.
- Faster rotation changes both the peak and the frequency.