🌡ThermodynamicsEdexcel A Level Physics · Topic 9
Spec point 145 · Topic 9 Thermodynamics

CP12 Thermistor Core practical 12: calibrating a thermistor as a thermostat

Big idea: A thermistor's resistance changes with temperature. Put it in a potential divider and the output voltage tells you the temperature – or switches a heater on and off.

Spec point 145 (in our words): Core practical 12: calibrating a thermistor in a potential divider to make a thermostat.
Official wording: Pearson Edexcel A level Physics (9PH0) specification

🧭 Plan: before you start

Before you start: what do you remember about Core practical 12: calibrating a thermistor as a thermostat from GCSE or earlier topics? Write down two things you know and one question you want answered.

How confident do you feel about this section right now?

From GCSE to A level

✔ You already know (GCSE)

  • An NTC thermistor's resistance falls as temperature rises.
  • In a series circuit the p.d. is shared between components.

★ New at A level

  • Calibration: measure V_out at known temperatures and draw a calibration curve (V_out against θ).
  • Use the curve to read an unknown temperature from a voltmeter reading.
  • Thermostat: the output voltage switches a heater (or fan) when it passes a set value. A variable resistor sets the temperature.
  • Choosing the fixed resistor to make the circuit most sensitive in the range you need.
GCSE link: GCSE Physics / Combined Science: electricity (thermistors and series circuits). Potential dividers are in Topic 3 of this course.

Key ideas

The circuit

  • A potential divider: a thermistor and a fixed (or variable) resistor in series across a supply of p.d. V.
  • V_out = V × R₂ ÷ (R₁ + R₂), where R₂ is the component the output is taken across.
  • For an NTC thermistor: hotter → lower resistance → smaller share of the p.d.
  • So V across the fixed resistor rises with temperature; V across the thermistor falls.

Method

  • Put the thermistor (in a sealed tube or waterproofed) and a thermometer in a beaker of water.
  • Heat the water slowly. Stir it so the temperature is the same everywhere.
  • At regular temperatures (e.g. every 10 °C from 0 °C with ice, to about 90 °C) record θ and V_out.
  • Wait for the readings to settle so the thermistor is at the same temperature as the water.
  • Plot V_out against θ. Draw a smooth curve. This is the calibration curve.

Using it as a thermostat

  • V_out goes to a switching circuit (e.g. a transistor or comparator) that turns a heater on or off.
  • Change the variable resistor to change the temperature at which it switches.
  • Swap the positions of the thermistor and resistor to switch on when it gets colder instead of hotter.

Getting good results

  • The output changes most quickly (most sensitive) when the fixed resistance is close to the thermistor's resistance in that range.
  • Sources of error: thermometer and thermistor not at the same temperature; water not stirred; reading the thermometer at an angle (parallax).
  • Safety: hot water and a hot plate – keep the beaker stable and do not touch the heater. Keep electrical parts dry.

⏸ Stop and check

Cover the notes above. Answer in your head, then reveal.

Explain without looking: NTC thermistor
Resistance falls as temperature rises.
Explain without looking: Calibration curve
V_out against θ from known temperatures; read unknown θ from it.

Diagrams

V+thermistorvariableresistor RVV_outto switch(heater on/off)hotter → thermistor R falls → V_out rises
Potential divider with an NTC thermistor and a variable resistor (UK symbols). The output p.d. across R rises as the thermistor gets hotter. R sets the switching temperature.
0V_out / Vtemperature θ / °C2040608012345reading 4.0 V → about 58 °C
A calibration curve: V_out measured at known temperatures (crosses), with a smooth curve drawn through them. Read across from a voltmeter reading to find an unknown temperature. (Example data.)

Key equations

EquationIn wordsUnits / notes
V_out = V × R₂ ÷ (R₁ + R₂)potential divider equationV
V₁ ÷ V₂ = R₁ ÷ R₂the p.d.s are in the same ratio as the resistances

⚠ Watch out! Common mistakes

  • An NTC thermistor's resistance falls when it gets hotter – not rises.
  • The calibration curve is usually not a straight line. Draw a smooth curve.
  • V across the thermistor and V across the resistor change in opposite directions; they always add up to the supply p.d.

💡 Exam tip

In a potential divider question, first decide which component the output is across. Then ask: does its share of the resistance go up or down?