From GCSE to A level
✔ You already know (GCSE)
- Magnets have N and S poles. Field lines go from N to S.
- Closer field lines mean a stronger field.
- A current in a wire or coil makes a magnetic field (an electromagnet).
- Higher tier: magnetic flux density B is measured in tesla (T), and F = BIl.
★ New at A level
- Magnetic flux Φ = BA, where A is the area at 90° to the field. Unit: weber (Wb).
- Flux linkage = NΦ for a coil with N turns. Unit: Wb-turns (or Wb).
- If the coil is at an angle, Φ = BA cos θ (θ between B and the normal to the coil).
- Changing flux linkage is what induces an e.m.f. (spec points 124–127).
GCSE link: AQA GCSE Combined Science 6.7 – Magnetism and electromagnetism (6.7.1 magnets and fields, 6.7.2 the motor effect).
Key ideas
Magnetic flux density B
- B tells you how strong a magnetic field is. Think of it as how crowded the field lines are.
- Unit: the tesla (T). 1 T is a strong field. A fridge magnet is about 0.01 T.
- Definition from F = BIl: 1 T is the flux density that gives a force of 1 N on 1 m of wire carrying 1 A at 90° to the field.
- B is a vector: it has a direction (N to S outside a magnet).
Magnetic flux Φ
- Φ = BA: flux = flux density × area, when the area is at 90° to the field.
- Think of it as the total number of field lines passing through the area.
- Unit: the weber (Wb). 1 Wb = 1 T m².
- So B is also "flux per unit area": B = Φ/A.
Coil at an angle
- Only the part of the field going through the coil counts.
- Φ = BA cos θ, where θ is the angle between B and the normal (a line at 90° to the coil face).
- Coil face at 90° to B (θ = 0): Φ = BA, the maximum.
- Coil face parallel to B (θ = 90°): Φ = 0. No lines go through.
Flux linkage NΦ
- A coil with N turns has the flux pass through each turn.
- Flux linkage = NΦ = BAN (for a coil at 90° to the field).
- Unit: Wb-turns (often just written Wb).
- Faraday's law: the induced e.m.f. depends on how fast NΦ changes (127).
Diagrams
Key equations
| Equation | In words | Units / notes |
|---|---|---|
| Φ = BA | flux = flux density × area (area at 90° to B) | Wb = T × m² |
| Φ = BA cos θ | θ between B and the normal to the coil | Wb |
| NΦ | flux linkage = turns × flux | Wb-turns |
| 1 T = 1 N A⁻¹ m⁻¹ | the tesla, from F = BIl | 1 Wb = 1 T m² |
⚠ Watch out! Common mistakes
- Flux density (B, in T) and flux (Φ, in Wb) are different things. Φ = BA.
- Area must be in m². 4.0 cm × 5.0 cm = 20 cm² = 2.0 × 10⁻³ m².
- θ is measured from the normal to the coil, not from the coil face. Read the diagram carefully.
- Flux linkage is NΦ. Do not forget to multiply by the number of turns.