☢Nuclear RadiationEdexcel A Level Physics · Topic 11
Spec point 171 · Topic 11 Nuclear Radiation

CP15 Gamma & lead Core practical 15: absorption of gamma radiation by lead

Big idea: Each extra millimetre of lead removes the same fraction of the gamma rays. So the count rate falls exponentially with thickness: C = C₀e^(−μx).

Spec point 171 (in our words): Core practical 15: how lead absorbs gamma radiation.
Official wording: Pearson Edexcel A level Physics (9PH0) specification

🧭 Plan: before you start

Before you start: what do you remember about Core practical 15: absorption of gamma radiation by lead from GCSE or earlier topics? Write down two things you know and one question you want answered.

How confident do you feel about this section right now?

From GCSE to A level

✔ You already know (GCSE)

  • Gamma is highly penetrating but is reduced by lead.

★ New at A level

  • A full method with a sealed gamma source, lead sheets and a GM tube.
  • Corrected count rate C = C₀e^(−μx), where μ is the absorption coefficient.
  • Plot ln C against x: a straight line with gradient −μ.
  • Half-thickness x½ = ln 2 ÷ μ. Safety with sources.
GCSE link: GCSE Physics / Combined Science: gamma radiation is reduced by thick lead. The exponential law is new.

Key ideas

Method

  • Measure the background count rate with no source present.
  • Fix a sealed gamma source (e.g. cobalt-60) and the GM tube a fixed distance apart (so the inverse square effect stays the same).
  • Count for a fixed time (e.g. 60 s) with no lead, then with lead sheets of increasing thickness x between them. Measure x with a micrometer.
  • Repeat each count and average. Subtract background to get the corrected count rate C.

Analysis

  • Gamma absorption is exponential: C = C₀e^(−μx).
  • Take logs: ln C = ln C₀ − μx. Plot ln C (y) against x (x-axis).
  • A straight line; gradient = −μ, y-intercept = ln C₀.
  • Half-thickness (thickness that halves the count): x½ = ln 2 ÷ μ. For cobalt-60 in lead it is about 1 cm (approximate).

Errors

  • Decay is random: count for longer, repeat, or use a stronger source.
  • Keep the source–tube distance fixed and the lead flat against the same position.
  • Some of the source may also emit beta – put a few mm of aluminium in front to absorb it first.
  • Lead sheets may not have exactly the stated thickness – measure them.

Safety

  • Handle sources with tongs, never with fingers. Keep them pointed away from people.
  • Keep sources in their lead-lined box when not in use. Minimise time, maximise distance.
  • Only use sealed sources under the supervision of a teacher. Wash hands after handling lead.

⏸ Stop and check

Cover the notes above. Answer in your head, then reveal.

Explain without looking: Absorption law
C = C₀e^(−μx)
Explain without looking: Half-thickness
x½ = ln 2 ÷ μ

Diagrams

sealed γ source(e.g. Co-60)Allead sheets, thickness xxGM tubecounterfixed distance
Core practical 15: lead sheets of increasing thickness are placed between a gamma source and a GM tube. The distance stays fixed and background is measured first.
0ln (corrected count rate)thickness of lead x / mm0510152025345gradient = −μintercept = ln C₀
Plot ln C against lead thickness x. A straight line shows exponential absorption; the gradient is −μ. (Example data.)

Key equations

EquationIn wordsUnits / notes
C = C₀e^(−μx)corrected count rate after thickness x of leads⁻¹
ln C = ln C₀ − μxstraight-line form: plot ln C against x
x½ = ln 2 ÷ μhalf-thicknessm

⚠ Watch out! Common mistakes

  • Subtract background before taking logs.
  • The graph of C against x is a curve – plot ln C against x for a straight line.
  • μ has units of m⁻¹ (or cm⁻¹, mm⁻¹) – it depends on the units of x.
  • Moving the source further away also lowers the count – that is the inverse square law, not absorption.

💡 Exam tip

Always say "background was subtracted" and "distance kept constant". Then: plot ln C against x, gradient = −μ.