☢Nuclear RadiationEdexcel A Level Physics · Topic 11
Spec point 168 · Topic 11 Nuclear Radiation

Background Background radiation

Big idea: Radiation is all around us all the time. Measure it first with no source, then subtract it from every reading.

Spec point 168 (in our words): Allowing for background radiation in calculations.
Official wording: Pearson Edexcel A level Physics (9PH0) specification

🧭 Plan: before you start

Before you start: what do you remember about Background radiation from GCSE or earlier topics? Write down two things you know and one question you want answered.

How confident do you feel about this section right now?

From GCSE to A level

✔ You already know (GCSE)

  • Background radiation comes from natural and man-made sources.
  • Radon gas is a big natural source.

★ New at A level

  • Measuring the background count rate over a long time.
  • Corrected count rate = measured count rate − background count rate.
  • Decay is random, so counts vary: count for longer to reduce the uncertainty.
  • When the source is weak, background matters a lot.
GCSE link: GCSE Physics / Combined Science: atomic structure (background radiation).

Key ideas

Where it comes from

  • Average UK dose ≈ 2.7 mSv per year (UK government figures).
  • Radon gas from rocks and soil – about half (48 % in the latest UK summary).
  • Medical (X-rays, scans) ≈ 16 %; rocks and buildings (gamma) ≈ 13 %; cosmic rays ≈ 12 %; food and drink ≈ 11 %.
  • Nuclear power, fallout and work exposure together are well under 1 %.

Measuring background

  • Remove all sources from the room (keep them in their lead-lined box, well away).
  • Switch on the GM tube and counter. Count for a long time (e.g. 5–10 minutes) and find counts per minute or per second.
  • Repeat and average: background varies randomly from minute to minute.
  • A typical school lab gives roughly 15–40 counts per minute (approximate – it depends on the tube and place).

Correcting your readings

  • Corrected count rate = measured count rate − background count rate.
  • Subtract before you plot graphs, take logs, or find half-lives.
  • Make sure both rates are in the same units (per second or per minute).
  • Example: measured 540 counts in 5 min = 108 min⁻¹. Background 25 min⁻¹. Corrected = 83 min⁻¹.

Random variation

  • Radioactive decay is random, so repeated counts are never exactly the same.
  • The uncertainty in a count N is roughly √N (beyond the spec, but useful): 100 counts ± 10 (10 %), 10 000 counts ± 100 (1 %).
  • So count for longer to get more counts and a smaller percentage uncertainty.

⏸ Stop and check

Cover the notes above. Answer in your head, then reveal.

Explain without looking: Background radiation
Radiation present all the time from natural and man-made sources.
Explain without looking: Correction
Corrected rate = measured rate − background rate.

Diagrams

48%16%13%12%11%radonmedicalground and buildingscosmicfood and drinkUK average ≈ 2.7 mSv per yearmeasuredbackgroundcorrectedcorrected = measured − background
Left: sources of background radiation, as shares of the average UK dose (UK government summary for 2023, rounded). Right: always subtract the background count rate.

Key equations

EquationIn wordsUnits / notes
corrected = measured − backgroundcount rates in the same unitss⁻¹ or min⁻¹
count rate = counts ÷ timeconvert counts to a rate firsts⁻¹

⚠ Watch out! Common mistakes

  • You subtract background count rates, not total counts from different times.
  • Background is not "zero indoors" – radon is often higher indoors.
  • One short background count is not enough – it varies randomly.
  • Do not subtract background twice (e.g. once from counts and again from the rate).

💡 Exam tip

In any data question, look for "background" in the stem. If it is there, the first mark is usually for subtracting it.