From GCSE to A level
✔ You already know (GCSE)
- Background radiation comes from natural and man-made sources.
- Radon gas is a big natural source.
★ New at A level
- Measuring the background count rate over a long time.
- Corrected count rate = measured count rate − background count rate.
- Decay is random, so counts vary: count for longer to reduce the uncertainty.
- When the source is weak, background matters a lot.
GCSE link: GCSE Physics / Combined Science: atomic structure (background radiation).
Key ideas
Where it comes from
- Average UK dose ≈ 2.7 mSv per year (UK government figures).
- Radon gas from rocks and soil – about half (48 % in the latest UK summary).
- Medical (X-rays, scans) ≈ 16 %; rocks and buildings (gamma) ≈ 13 %; cosmic rays ≈ 12 %; food and drink ≈ 11 %.
- Nuclear power, fallout and work exposure together are well under 1 %.
Measuring background
- Remove all sources from the room (keep them in their lead-lined box, well away).
- Switch on the GM tube and counter. Count for a long time (e.g. 5–10 minutes) and find counts per minute or per second.
- Repeat and average: background varies randomly from minute to minute.
- A typical school lab gives roughly 15–40 counts per minute (approximate – it depends on the tube and place).
Correcting your readings
- Corrected count rate = measured count rate − background count rate.
- Subtract before you plot graphs, take logs, or find half-lives.
- Make sure both rates are in the same units (per second or per minute).
- Example: measured 540 counts in 5 min = 108 min⁻¹. Background 25 min⁻¹. Corrected = 83 min⁻¹.
Random variation
- Radioactive decay is random, so repeated counts are never exactly the same.
- The uncertainty in a count N is roughly √N (beyond the spec, but useful): 100 counts ± 10 (10 %), 10 000 counts ± 100 (1 %).
- So count for longer to get more counts and a smaller percentage uncertainty.
Diagrams
Key equations
| Equation | In words | Units / notes |
|---|---|---|
| corrected = measured − background | count rates in the same units | s⁻¹ or min⁻¹ |
| count rate = counts ÷ time | convert counts to a rate first | s⁻¹ |
⚠ Watch out! Common mistakes
- You subtract background count rates, not total counts from different times.
- Background is not "zero indoors" – radon is often higher indoors.
- One short background count is not enough – it varies randomly.
- Do not subtract background twice (e.g. once from counts and again from the rate).