From GCSE to A level
✔ You already know (GCSE)
- Independent, dependent and control variables.
- Repeat readings and find a mean.
- Draw results tables and graphs.
- Basic risk assessment.
★ New at A level
- Reading a micrometer (to 0.01 mm) and a vernier calliper (to 0.1 mm or better).
- Techniques that cut uncertainty: timing many oscillations, using a fiducial marker, checking for zero errors, avoiding parallax.
- The 16 Edexcel core practicals and the CPAC skills your teacher records.
- Applying the same ideas to an unfamiliar experiment in the exam.
GCSE link: GCSE Physics / Combined Science: required practicals and "Working scientifically" (variables, risk, recording results).
Key ideas
Variables
- Independent variable: the one you change.
- Dependent variable: the one you measure.
- Control variables: the ones you keep the same so the test is fair.
- In the exam, name the variables precisely, e.g. "the length of the wire between the crocodile clips", not just "length".
Choosing an instrument
- Pick the instrument with a resolution small enough for the size of the measurement.
- Metre rule: 1 mm. Vernier calliper: 0.1 mm (some are 0.02 mm). Micrometer: 0.01 mm. Digital meters: last digit shown.
- Use a micrometer for a wire diameter (about 0.3 mm). A ruler would give a huge percentage uncertainty.
- Light gates and data loggers remove reaction time from timing.
Techniques that improve results
- Repeat readings and find a mean – this reduces the effect of random errors.
- Time many oscillations (e.g. 20) and divide, so the reaction-time error is shared out.
- Use a fiducial marker (a fixed pin or line) to start and stop timing at the same point.
- Check for zero error before you start. Read scales at eye level to avoid parallax.
- Measure a wire diameter at several places and in different directions, then take a mean.
Safety and CPAC
- Assess risks and say how to reduce them, e.g. goggles for stretched wires, a sand tray under hanging masses, tongs for radioactive sources.
- Edexcel uses the Common Practical Assessment Criteria (CPAC): follow written procedures, use equipment and methods, work safely, make and record observations, and research and report.
- There are 16 core practicals, from free fall (CP1) to finding a mass using resonance (CP16).
- In unfamiliar experiments: identify variables, choose instruments, plan repeats, think about safety, and say how you would analyse the results (usually a straight-line graph).
Diagrams
Key equations
| Equation | In words | Units / notes |
|---|---|---|
| micrometer reading = sleeve (mm) + thimble division × 0.01 mm | add the sleeve scale and the thimble scale | mm |
| vernier reading = main scale (mm) + matching vernier line × 0.1 mm | for a 10-division vernier | mm |
| T = total time ÷ number of oscillations | time many swings, then divide | s |
⚠ Watch out! Common mistakes
- Repeating readings does not remove a systematic error such as a zero error – it only reduces random error.
- A more precise instrument is not automatically more accurate – it may still have a zero error.
- A digital stopwatch reads to 0.01 s, but your reaction time (very roughly 0.2 s) is a much bigger uncertainty.
- Control variables are kept the same; they are not "the things you don't measure".