Step 1 of 6 Plan the practical
Aim
Find the e.m.f. ε and the internal resistance r of a cell.
The terminal p.d. is V = ε − Ir. A graph of V against I is a straight line: the y-intercept is ε and the gradient is −r.
📋 Specification: “Determine the e.m.f. and internal resistance of an electrical cell.”
Equipment
- a cell in a holder
- a variable resistor (rheostat), or a resistance box
- a switch
- an ammeter and a voltmeter (or digital multimeters)
- connecting leads
- (sometimes a small fixed resistor in series, to protect the cell)
Method
- Connect the cell, switch, ammeter and variable resistor in series.
- Connect the voltmeter across the cell, to measure the terminal p.d.
- Set the variable resistor to its largest value. Close the switch, record V and I, then open the switch.
- Decrease the resistance in steps and repeat, to get at least 8 pairs of readings over a wide range of current.
- Plot V against I and draw a line of best fit.
- The y-intercept is the e.m.f. ε; the gradient is −r.
Step 2 of 6 Variables and risks
Variables: what changes, what you measure, what stays the same
The quiz needs JavaScript. The answers are in the table below.
The variables in this practical
| Variable | In this practical |
|---|---|
| Independent | The current I (changed with the variable resistor) |
| Dependent | The terminal p.d. V |
| Control | The same cell, kept at a steady temperature (switch open between readings) |
Risks
| Hazard | What could happen | How to reduce the risk |
|---|---|---|
| Short-circuiting the cell (very low resistance) | The cell and leads get hot; the cell could leak | Never set the resistance to zero; use a protective resistor if needed; open the switch between readings. |
| Hot resistor | Burns | Do not touch the variable resistor during the experiment. |
Step 3 of 6 Do the practical
Simulator
Put the variable resistor, ammeter, switch and voltmeter in the right places. Then change the resistance and read the meters – but close the switch only while you read them.
Step 4 of 6 Results and graph
Help: how to analyse the results
Plot V (y) against I (x). Compare with y = mx + c: V = −rI + ε, so the gradient = −r and the y-intercept = ε.
The "lost volts" Ir grow as the current grows, so the terminal p.d. falls. A brand-new 1.5 V cell typically has ε ≈ 1.5–1.6 V and r of under 1 Ω (values vary).
Step 5 of 6 Conclusion and evaluation
Conclusion
Show a model conclusion
The y-intercept of my graph is 1.56 V, so the e.m.f. of the cell is 1.56 V. The gradient is −0.81 V A⁻¹, so the internal resistance is 0.81 Ω.
Errors and how to improve
- Cell warming up: its internal resistance changes – close the switch only while reading.
- Cell running down: the e.m.f. falls over time – take readings quickly, in a random order.
- Meter resolution: use meters that read to 0.01 V and 0.001 A.
- Too narrow a range: the intercept is less certain – use a wide range of currents.
Uncertainties
Find the uncertainty in r from the gradients of the steepest and least steep acceptable lines: ±½ × (difference).
Find the uncertainty in ε from the intercepts of the same two lines. The intercept is an extrapolation, so its uncertainty grows if your readings are far from I = 0.
Step 6 of 6 Exam-style question
A student wants to find the e.m.f. and internal resistance of a cell.
Describe a method the student could use, including a circuit diagram and how the results are analysed.
[6 marks]
Mark scheme (level of response)
| Level | What the answer needs |
|---|---|
| 3 (5–6 marks) | A correct circuit, a detailed method with a wide range of readings and good technique, and the graph with how both ε and r are found. |
| 2 (3–4 marks) | A mostly correct circuit and method, but some detail is missing (for example only one of ε or r explained). |
| 1 (1–2 marks) | Some relevant steps, but not a method someone could follow. |
| 0 | Nothing worth a mark. |
Tick the points your answer includes
Show a model answer
Connect the cell in series with a switch, an ammeter and a variable resistor, and connect a voltmeter across the cell. Set the variable resistor to a high value, close the switch, record the terminal p.d. V and the current I, then open the switch so the cell does not warm up. Reduce the resistance in steps and repeat to get at least eight pairs of readings over a wide range of currents. Plot V against I and draw a line of best fit. Since V = ε − Ir, the intercept on the V axis is the e.m.f. and the gradient is −r, so the internal resistance is minus the gradient.
This is an exam-style question written for this website. It is not a real Edexcel question.