Step 1 of 6 Plan the practical
Aim
Investigate how the count rate of gamma radiation falls as it passes through more lead.
The corrected count rate falls exponentially: C = C₀e−μx, where μ is the absorption coefficient. A graph of ln C against thickness x is a straight line with gradient −μ.
📋 Specification: “Investigate the absorption of gamma radiation by lead.”
Equipment
- a sealed gamma source (cobalt-60) in a holder, and tongs
- a Geiger–Müller tube and counter
- lead sheets of different thickness
- a micrometer
- a stopwatch (if the counter has no timer)
Method
- With the source in its lead box, measure the background count for at least 5 minutes. Work out the background count rate.
- Using tongs, put the source in the holder facing the GM tube, a fixed distance away.
- Record the count for a fixed time (100 s or more) with no lead.
- Measure the thickness of a lead sheet with a micrometer, place it between the source and the tube, and record the count.
- Repeat with more sheets, measuring the total thickness each time.
- Correct every count rate by subtracting the background rate. Plot ln C against x.
- Return the source to its box as soon as you have finished.
Step 2 of 6 Variables and risks
Variables: what changes, what you measure, what stays the same
The quiz needs JavaScript. The answers are in the table below.
The variables in this practical
| Variable | In this practical |
|---|---|
| Independent | Thickness of lead x |
| Dependent | Count rate (corrected for background) C |
| Control | The distance between source and tube; the counting time; the same source |
Risks
| Hazard | What could happen | How to reduce the risk |
|---|---|---|
| Ionising radiation from the source | Damage to cells; increased cancer risk | Use tongs at arm’s length; never point it at anyone; keep it out of its box for as short a time as possible; wash hands afterwards. |
| Lead sheets | Lead is toxic | Wear gloves or wash hands after handling. |
Step 3 of 6 Do the practical
Simulator
Use tongs to handle the source. Measure the background count first, then count with more and more lead. Press Test my setup for hints.
Step 4 of 6 Results and graph
Help: how to analyse the results
Count rate = count ÷ time. Subtract the background rate to get C. Plot ln C against x; the gradient is −μ. The half-value thickness (the thickness that halves the count rate) is ln 2 ÷ μ.
Sources quote a half-value thickness of roughly 1 cm of lead for cobalt-60 gamma rays; the exact value depends on the setup. You may want to verify this from a data book.
Step 5 of 6 Conclusion and evaluation
Conclusion
Show a model conclusion
The gradient of ln C against x was −0.059 mm⁻¹, so μ = 0.059 mm⁻¹ and the half-value thickness is ln 2 ÷ 0.059 = 11.7 mm.
Errors and how to improve
- Randomness: radioactive decay is random. Count for longer (or repeat) so each count is large.
- Background: measure it carefully and subtract it from every count.
- Distance: moving the source or tube changes the count rate (inverse square law) – keep it fixed.
- Dead time: at very high count rates the GM tube misses some counts.
Uncertainties
Counts: for a count N, the uncertainty is about √N. For 1000 counts that is ±32 (3%); for 100 counts it is ±10 (10%).
Thickness: a micrometer reads to ±0.01 mm. The counts are the main source of uncertainty – show them as error bars on ln C.
Step 6 of 6 Exam-style question
A student is asked to investigate how the count rate from a gamma source changes with the thickness of lead between the source and a GM tube.
Describe how she should carry out the experiment safely and how she should analyse the results.
[6 marks]
Mark scheme (level of response)
| Level | What the answer needs |
|---|---|
| 3 (5–6 marks) | A detailed, logical method: background count, safe handling, fixed distance, thickness measured, long counts, corrected rates and the ln C–x graph. |
| 2 (3–4 marks) | The main steps, but some detail is missing (for example no background correction or no graph). |
| 1 (1–2 marks) | Some relevant steps, but not a method someone could follow. |
| 0 | Nothing worth a mark. |
Tick the points your answer includes
Show a model answer
With the source in its box, record the background count for five minutes and work out the background count rate. Using tongs and holding the source at arm’s length, place it in a holder a fixed distance from the GM tube. Record the count for 100 s with no lead. Measure the thickness of a lead sheet with a micrometer, place it between the source and the tube, and record the count for 100 s. Repeat with more sheets, measuring the total thickness each time. Work out each count rate and subtract the background rate. Plot ln of the corrected count rate against thickness; a straight line shows the absorption is exponential, and the gradient is −μ. Return the source to its box as soon as possible.
This is an exam-style question written for this website. It is not a real Edexcel question.