Step 1 of 6 Plan the practical
Aim
Calibrate a thermistor in a potential divider so that it can be used as a thermostat.
As the temperature rises, the resistance of an NTC thermistor falls. In series with a fixed resistor, the p.d. across the fixed resistor rises. A calibration curve of output p.d. against temperature lets you read the temperature from the p.d., or choose the p.d. at which a switch should turn a heater on or off.
📋 Specification: “Calibrate a thermistor in a potential divider circuit as a thermostat.”
Equipment
- an NTC thermistor (in a waterproof tube)
- a fixed resistor (10 kΩ) and a 5.0 V supply
- a voltmeter
- a beaker of water, ice, a kettle
- a thermometer and a stirrer
Method
- Connect the thermistor in series with the fixed resistor across the 5.0 V supply. Connect the voltmeter across the fixed resistor.
- Put the thermistor and the thermometer side by side in a beaker of water with ice, at about 0 °C.
- Stir, wait for the readings to be steady, then record the temperature and the output p.d.
- Add hot water a little at a time to raise the temperature in steps of about 10 °C. Stir and record each time, up to about 90 °C.
- Plot the output p.d. against the temperature and draw a smooth curve: this is the calibration curve.
- Use the curve to find the p.d. at the temperature you want the thermostat to switch at.
Step 2 of 6 Variables and risks
Variables: what changes, what you measure, what stays the same
The quiz needs JavaScript. The answers are in the table below.
The variables in this practical
| Variable | In this practical |
|---|---|
| Independent | Temperature θ |
| Dependent | Output p.d. V |
| Control | The supply p.d.; the fixed resistor |
Risks
| Hazard | What could happen | How to reduce the risk |
|---|---|---|
| Hot water from the kettle | Scalds | Pour carefully; stand up; keep the beaker away from the edge. |
| Water and electricity | Shock or damage | Keep the circuit dry; use a low-voltage supply and a waterproofed thermistor. |
Step 3 of 6 Do the practical
Simulator
Set up the water bath and the circuit. Change the temperature with ice and hot water, and stir before each reading. Press Test my setup for hints.
Step 4 of 6 Results and graph
Help: how to analyse the results
Plot V (y-axis) against θ (x-axis) and draw a smooth curve. It is not a straight line, because the thermistor’s resistance falls roughly exponentially with temperature.
The thermostat is most sensitive where the curve is steepest. To make the thermostat switch at a different temperature, change the fixed resistor (or use a variable resistor).
Step 5 of 6 Conclusion and evaluation
Conclusion
Show a model conclusion
The output p.d. rose from 1.1 V at 0 °C to 4.6 V at 90 °C, most steeply between 20 °C and 50 °C. To keep water at 40 °C, the heater should switch off when the output reaches 3.27 V.
Errors and how to improve
- Temperature not uniform: stir before every reading, and keep the thermistor next to the thermometer bulb.
- Readings changing: wait until both meters are steady.
- Self-heating: the current warms the thermistor a little; use a small current.
- Heat loss: the temperature falls while you read – read both meters at the same time.
Uncertainties
Thermometer: ±0.5 °C (half a division). Voltmeter: ±0.01 V.
The uncertainty in a temperature read from the curve depends on the gradient: where the curve is flat, a small error in V gives a large error in θ.
Step 6 of 6 Exam-style question
A student wants to use an NTC thermistor in a potential divider as a thermostat to keep a tank of water at 40 °C.
Describe how she should calibrate the potential divider and use the calibration to set the thermostat.
[6 marks]
Mark scheme (level of response)
| Level | What the answer needs |
|---|---|
| 3 (5–6 marks) | A detailed, logical method: the circuit, a water bath with thermometer, a range of temperatures, stirring, the calibration curve and how it is used. |
| 2 (3–4 marks) | The main steps, but some detail is missing (for example how the curve is used to set 40 °C). |
| 1 (1–2 marks) | Some relevant steps, but not a method someone could follow. |
| 0 | Nothing worth a mark. |
Tick the points your answer includes
Show a model answer
Connect the thermistor in series with a fixed resistor across a 5 V supply, with a voltmeter across the fixed resistor. Put the waterproofed thermistor next to a thermometer in a beaker of water and ice. Stir, wait for steady readings, and record the temperature and the p.d. Add hot water to raise the temperature in steps of about 10 °C up to 90 °C, stirring and recording each time. Plot the p.d. against temperature and draw a smooth calibration curve. Read off the p.d. at 40 °C. The thermostat switch is then set so that it turns the heater off when the output reaches this p.d., and on when it falls below it.
This is an exam-style question written for this website. It is not a real Edexcel question.