Edexcel A level · Year 13 · Topic 9 · Thermodynamics

Core practical 12: Thermistor thermostat

Calibrate a thermistor potential divider in a water bath, then use it to set a temperature. Use the instruments in the simulator, analyse your own results, then learn the method and uncertainties for the exam.

Edexcel A level CP12Year 13 · Topic 9 · Thermodynamics

Step 1 of 6 Plan the practical

Aim

Calibrate a thermistor in a potential divider so that it can be used as a thermostat.

As the temperature rises, the resistance of an NTC thermistor falls. In series with a fixed resistor, the p.d. across the fixed resistor rises. A calibration curve of output p.d. against temperature lets you read the temperature from the p.d., or choose the p.d. at which a switch should turn a heater on or off.

📋 Specification: “Calibrate a thermistor in a potential divider circuit as a thermostat.”

Equipment

  • an NTC thermistor (in a waterproof tube)
  • a fixed resistor (10 kΩ) and a 5.0 V supply
  • a voltmeter
  • a beaker of water, ice, a kettle
  • a thermometer and a stirrer

Method

  1. Connect the thermistor in series with the fixed resistor across the 5.0 V supply. Connect the voltmeter across the fixed resistor.
  2. Put the thermistor and the thermometer side by side in a beaker of water with ice, at about 0 °C.
  3. Stir, wait for the readings to be steady, then record the temperature and the output p.d.
  4. Add hot water a little at a time to raise the temperature in steps of about 10 °C. Stir and record each time, up to about 90 °C.
  5. Plot the output p.d. against the temperature and draw a smooth curve: this is the calibration curve.
  6. Use the curve to find the p.d. at the temperature you want the thermostat to switch at.
V5.0 V10 kΩthermistorthermometerwater bath
The output is the p.d. across the fixed resistor.

← All core practicals