Step 1 of 6 Plan the practical
Aim
Use a data logger to record the p.d. across a capacitor as it discharges and charges through a resistor, and find its capacitance.
When discharging, V = V₀e−t/RC, so ln V = ln V₀ − t/RC. A graph of ln V against t is a straight line with gradient −1/RC.
📋 Specification: “Use an oscilloscope or data logger to display and analyse the potential difference across a capacitor as it charges and discharges through a resistor.”
Equipment
- a capacitor (about 1000 µF) and a resistor (about 47 kΩ)
- a battery or d.c. supply (about 9 V)
- a two-way switch and connecting leads
- a voltage sensor and data logger (or a voltmeter and stopwatch)
Method
Discharging
- Set up the circuit. Connect the voltage sensor across the capacitor.
- Move the switch to A to charge the capacitor fully.
- Start the data logger, then move the switch to B. The capacitor discharges through the resistor.
- Record the p.d. every 10 s (or read values from the logger’s graph) for at least 2 minutes.
- Plot ln V against t. The gradient is −1/RC, so C = −1/(gradient × R).
Charging
- Discharge the capacitor fully. Start the logger, then move the switch to A.
- Plot V against t. Read V₀ from the flat part of the curve.
- Find the time for V to reach 0.63 V₀ – this is the time constant τ = RC.
Step 2 of 6 Variables and risks
Variables: what changes, what you measure, what stays the same
The quiz needs JavaScript. The answers are in the table below.
The variables in this practical
| Variable | Discharging | Charging | |
|---|---|---|---|
| Independent | Time t | Time t | |
| Dependent | p.d. across the capacitor V | p.d. across the capacitor V | |
| Control | The same resistor, capacitor and supply | The same resistor, capacitor and supply |
Risks
| Hazard | What could happen | How to reduce the risk |
|---|---|---|
| Electrolytic capacitor connected the wrong way round | It can overheat or burst | Connect the + terminal to the positive side; stay within its voltage rating. |
| Charged capacitor | A small shock or a spark | Discharge it through the resistor before handling it. |
Step 3 of 6 Do the practical
Simulator
There are two parts: discharging and charging. Use the tabs. Build the circuit, start the logger, then move the switch. Press Test my setup for hints.
Step 4 of 6 Results and graph
Help: how to analyse the results
Discharging: ln V against t is a straight line. τ = RC = −1/gradient, so C = τ/R.
Charging: V = V₀(1 − e−t/RC). After one time constant, V = 0.63 V₀; after 5 time constants it is over 99% charged. Electrolytic capacitors often have a tolerance of ±20%, so the label value is only a guide.
Step 5 of 6 Conclusion and evaluation
Conclusion
Show a model conclusion
The gradient of ln V against t was −0.0226 s⁻¹, so RC = 44.2 s and C = 44.2 ÷ 47 000 = 940 µF. The label says 1000 µF ± 20%, so this is within the tolerance.
Errors and how to improve
- Resistance of the meter: a voltmeter with a low resistance gives another path for discharge. A data logger has a very high resistance.
- Resistor tolerance: use the measured value of R if possible.
- Reaction time (with a stopwatch): use a large time constant, or a data logger.
- Small p.d.s: at the end of the discharge, small errors in V give large errors in ln V.
Uncertainties
p.d.: the logger reads to 0.01 V; on 1.00 V that is 1%, on 8.00 V only 0.1%.
Resistor: typically ±1% or ±5% (read the bands).
% uncertainty in C = % in the gradient + % in R. Draw the steepest and shallowest acceptable lines to find the uncertainty in the gradient.
Step 6 of 6 Exam-style question
A student wants to determine the capacitance of a capacitor by discharging it through a resistor of known resistance.
Describe how she should carry out the experiment and use the results to find the capacitance.
[6 marks]
Mark scheme (level of response)
| Level | What the answer needs |
|---|---|
| 3 (5–6 marks) | A detailed, logical method: the circuit, charging then discharging, measuring V at regular times, plotting ln V against t and finding C from the gradient. |
| 2 (3–4 marks) | The main steps, but some detail is missing (for example how C is found from the graph). |
| 1 (1–2 marks) | Some relevant steps, but not a method someone could follow. |
| 0 | Nothing worth a mark. |
Tick the points your answer includes
Show a model answer
Set up a circuit with the supply, a two-way switch, the resistor and the capacitor, with a voltage sensor connected to a data logger across the capacitor. Move the switch so the capacitor charges fully. Start the logger and move the switch so the capacitor discharges through the resistor. Record the p.d. every 10 s for at least two minutes. Work out ln V for each reading and plot ln V against t. This is a straight line because ln V = ln V0 − t/RC, so the gradient is −1/RC. Then C = −1/(gradient × R). A data logger has a very high resistance, so it does not discharge the capacitor itself.
This is an exam-style question written for this website. It is not a real Edexcel question.